MIL-DTL-24643/33F
TABLE I. Details.
Overall diameter
Cable jacket
Military part no.
Number of
thickness min
Type and size
min.
max.
M24643/33
pairs
avg. (inch)
(inch)
(inch)
-01UN
LS2SWU-1
1
0.015
0.240
0.255
-02UN
LS2SWU-3
3
0.075
0.670
0.710
-03UN
LS2SWU-7
7
0.075
0.860
0.910
-04UN
LS2SWU-12
12
0.088
1.130
1.200
-05UN
LS2SWU-19
19
0.100
1.292
1.380
-06UN
LS2SWU-24
24
0.100
1.500
1.590
-07UN
LS2SWU-30
30
0.100
1.670
1.760
-08UN
LS2SWU-37
37
0.125
1.785
1.870
-09UN
LS2SWU-61
61
0.125
2.205
2.300
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
7.47
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to shield
1000
Component shield to component shield
500
Insulation resistance (megohms.1000 feet, min.)
Conductor to conductor
500
Conductor to shield
500
Component shield to component shield
100
Conductor continuity
No failure
Shield continuity
No failure
Group A:
Visual and dimensional
No failure
Hydrostatic (open end) (leakage at 300 lb/in2, 2 hours, in³, max.)
1.0
Capacitance
Mutual capacitance, at 1 kilohertz (KHz) (pF/ft, max.)
30
Capacitance unbalance (percent max.)
8
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business