MIL-DTL-24643/32F
TABLE I. Details.
Overall diameter
Cable jacket
Military part no.
Number of
thickness min
Type and size
min.
max.
M24643/32
pairs
avg. (inch)
(inch)
(inch)
-01UN
LS2SWAU-3
3
0.050
0.480
0.520
-02UN
LS2SWAU-7
7
0.050
0.610
0.660
-03UN
LS2SWAU-10
10
0.050
0.770
0.830
-04UN
LS2SWAU-14
14
0.063
0.860
0.930
-05UN
LS2SWAU-19
19
0.063
0.970
1.040
-06UN
LS2SWAU-24
24
0.063
1.120
1.210
-07UN
LS2SWAU-30
30
0.063
1.190
1.280
-08UN
LS2SWAU-37
37
0.063
1.290
1.380
-09UN
LS2SWAU-44
44
0.063
1.460
1.550
-10UN
LS2SWAU-61
61
0.075
1.660
1.740
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
17.37
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to shield
1000
Component shield to component shield
500
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to shield
500
Component shield to component shield
100
Conductor continuity
No failure
Shield continuity
No failure
Group A:
Visual and dimensional
No failure
Hydrostatic (open end) (leakage at 300 lb/in2, 2 hours, in3, max.)
1.0
Capacitance
Mutual capacitance, at 1 kilohertz (KHz) (pF/ft, max.)
30
Capacitance unbalance (percent max.)
8
2