MIL-DTL-24643/30F
TABLE I. Details.
Overall diameter
Cable jacket
Military part no.
Number of
thickness min. avg.
Type and size
Min.
Max.
M24643/30
conductors
(inch)
(inch)
(inch)
-01UN
LS1SWU-2
2
0.038
0.430
0.455
-02UN
LS1SWU-14
14
0.050
0.825
0.870
-03UN
LS1SWU-20
20
0.050
0.970
1.030
-04UN
LS1SWU-30
30
0.063
1.135
1.200
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
17.2
Voltage withstand (volts, root mean square, min.)
Conductor to component shield
3000
Component shield to component shield
500
Insulation resistance (megohms/1000 feet, min.)
Conductor to component shield
500
Component shield to component shield
100
Conductor continuity
No failure
Shield continuity
No failure
Group A:
Visual and dimensional
No failure
Hydrostatic (open end) (leakage at 300 lb/in2, 2 hours, in3, max.)
1.0
Capacitance (mutual), at 1 kilohertz (KHz) (pF/ft, max.)
28
Characteristic impedance, at 1 megahertz (MHz) (ohms)
61±3
Group B:
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
2