TABLE I. Details - Continued.
Overall
Roller dia.
Insulation
Jacket wall
Conductor size
Military
Conductor
Insulation
diameter
for bending
thickness
Type and
Number of
thickness
part no.
resistance
resistance
endurance
min. avg.
min. avg.
size
conductors
Navy
min.
max.
24643/3
(ohms)
(megohm)
(max.)
AWG
(inch)
(inch)
std.
(inch)
(inch)
(inch)
-20UN
LSTHOF-3
16 (Class K)
0.031
3
0.040
0.430
0.450
1.4
4.36
300
-21UN
LSTHOF-4
14 (Class K)
0.031
3
0.040
0.460
0.480
1.4
2.73
250
-22UN
LSTHOF-6
12 (Class K)
0.031
3
0.050
0.520
0.550
1.7
1.72
200
-23UN
LSTHOF-9
9(90)
0.031
3
0.050
0.570
0.600
1.8
1.24
200
-24UN
LSTHOF-14
14 (140)
0.040
3
0.050
0.720
0.750
2.3
0.802
200
-25UN
LSTHOF-23
7 (Class K)
0.040
3
0.050
0.860
0.900
3.5
0.560
150
-26UN
LSTHOF-42
42 (209)
0.070
3
0.070
1.200
1.250
4.5
0.277
150
-27UN
LSTHOF-150
150 (760)
0.070
3
0.100
1.740
1.820
0.0762
125
250
0.070
3
0.100
2.140
2.240
0.0462
100
-28UN
LSTHOF-250
(1254)
400
0.090
3
0.100
2.680
2.800
0.0283
100
-29UN
LSTHOF-400
(2052)
500 MCM
0.090
3
0.100
2.920
3.100
0.0230
100
-30UN
LSTHOF-500
(Class K)
600 MCM
0.100
3
0.100
2.980
3.150
0.0200
100
-31UN
LSTHOF-600
(Class G)
-32UN
LSFHOF-3
16 (Class K)
0.031
4
0.040
0.460
0.480
1.4
4.36
300
-33UN
LSFHOF-4
14 (Class K)
0.031
4
0.040
0.520
0.550
1.6
2.73
250
-34UN
LSFHOF-9
9(90)
0.031
4
0.050
0.630
0.660
1.8
1.24
200
-35UN
LSFHOF-42
42 (209)
0.070
4
0.070
1.300
1.380
4.1
0.277
150
-36UN
LSFHOF-60
60 (304)
0.070
4
0.070
1.430
1.510
4.5
0.191
150
-37UN
LSFHOF-133
133 (684)
0.070
4
0.100
1.920
2.000
0.0847
125
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business