MIL-DTL-24643/28F
Overall shield to overall shield (Type LS1S50MUS only)
100
Conductor continuity
No failure
Shield continuity
No failure
Jacket flaws (Type LS1S50MUS only)
No failure
Group A:
Visual and dimensional
No failure
Characteristic impedance, at 1 megahertz (MHz) (ohms)
50±2
Group B:
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Attenuation, at 400 MHz (decibel (db)/100 ft max.)
18
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
Group C:
Physicals (aged) air oven
Insulation (extruded)
Tensile strength (percent of unaged, min.)
75
Elongation (percent of unaged, min.)
75
Jacket (cable)
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
Permanence of printing (jacket) (cycles, min.)
125
Heat distortion (percent of unaged, max.)
30
Shrinkage
No failure
Shield (conformance to material, construction and coverage)
No failure
Surface transfer impedance (Type LS1S50MUS only)
3