MIL-DTL-24643/26F
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
See table I
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
3000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
NOTE: The nickel coating on the conductors of the completed shall be permitted to have minor nicks,
scrapes, or abrasions that are just perceptible to the eye.
Watertightness (Types LSDPS, LSTPS, LSFPS, and LS7PS only)
No failure
(see MIL-DTL-24643 for limits of water leakage)
Abrasion resistance minimum
75
Crack resistance
No damage
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Drip (9±1 °C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
800
Elongation (percent, min.)
250
Durometer (jacket) - Type A (hardness, min.)
60
Gas flame (1 hour)
No failure
3