MIL-DTL-24643/22E
TABLE I. Details.
Cable
Conductor size
Accelerated
Conductor
Insulation
overall
Military part no.
service
resistance
resistance
Type and size
diameter
loading
M24643/22
Navy std
AWG
(ohms)
(megohms)
max.
ampere
(inches)
-01UN
LS5KVTSGU-100
100
0 (Class D)
1.74
0.106
400
295
000
1.95
0.0674
350
400
-02UN
LS5KVTSGU-150
150
(Class D)
250 MCM
2.22
0.0453
300
535
-03UN
LS5KVTSGU-250
250
(Class C)
350 MCM
2.45
0.0321
265
665
-04UN
LS5KVTSGU-350
350
(Class D)
-05UN
LS5KVTSGU-400
400 (127)
2.60
0.0273
250
750
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
See table I
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
13500
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
See table I
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Watertightness (see MIL-DTL-24643 for limits of water leakage)
No failure
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation (extruded insulations only)
50
Jacket (when tested at 200 °C)
50
Drip (95±1 °C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
2