MIL-DTL-24643/17F
Insulation
45
Toxicity index (max.)
Jacket
5
Fillers
5
Insulation
1.5
Durometer (jacket) - Type A (hardness, min.)
80
Weathering (jacket)
No failure
Electrical moisture absorption (extruded insulations only)
No failure
UNIT ORDERING LENGTHS:
Type
Size
Feet (nominal)
LSFSGU
3
2500
LSFSGU
4 and 9
2000
LSFSGU
23 and 50
1500
LSFSGU
75 through 150
1000
LSFSGU
200
500
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with
respect to the previous issue due to the extent of the changes.
Custodians:
Preparing Activity:
Army MI
Navy SH
Navy SH
(Project 6145-2008-021)
Review Activities:
Army AR, AV, CR
Navy CG, EC
DLA CC
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.daps.dla.mil.