TABLE I. Details.
Jacket
Conductor size
Cable overall
Insulation
Conductor
Insulation
Accelerated
Military part
thickness
diameter
Type and size
thickness min.
resistance
resistance
service loading
Navy
no. M24643/15
min. avg.
AWG
max. (inch)
avg. (inch)
(ohms)
(megohms)
ampere
std
(inch)
-01UN
LSDSGU-3
16 (Class B)
0.391
0.018
0.030
4.3
500
-02UN
LSDSGU-4
14 (Class B)
0.427
0.018
0.030
2.68
500
-03UN
LSDSGU-9
10 (Class B)
0.544
0.015
0.040
1.08
500
-04UN
LSDSGU-14
9 (Class B)
0.670
0.018
0.040
0.859
500
100
-05UN
LSDSGU-23
7 (Class B)
0.781
0.035
0.050
0.543
500
130
-06UN
LSDSGU-50
3 (Class C)
0.911
0.035
0.050
0.210
200
215
-07UN
LSDSGU-75
1 (Class C)
1.074
0.035
0.050
0.134
175
285
-08UN
LSDSGU-100
0 (Class D)
1.167
0.035
0.050
0.106
160
335
-09UN
LSDSGU-200
0000 (Class D)
1.583
0.050
0.060
0.053
125
525
300 MCM
1.841
0.050
0.075
0.0377
110
700
-10UN
LSDSGU-300
(Class D)
400
2.069
0.050
0.075
0.0273
100
835
-11UN
LSDSGU-400
(127)
For Parts Inquires call Parts Hangar, Inc (727) 493-0744