TABLE I. Details.
Cable
Jacket
Accelerated
Conductor size
Insulation
Conductor
Insulation
Military part no.
overall
thickness
service
Type and size
thickness min.
resistance
resistance
Navy
M24643/14
diameter
min. avg.
loading
AWG
avg. (inch)
max. (ohms)
(megohms)
std
max. (inch)
(inch)
amperes
-01UN
LSSSGU-50
3 (Class C)
0.520
0.035
0.209
0.040
160
240
-02UN
LSSSGU-75
1 (Class C)
0.602
0.035
0.132
0.040
135
315
-03UN
LSSSGU-100
0 (Class D)
0.669
0.040
0.105
0.050
125
375
0000
0.872
0.050
0.0525
0.050
90
580
-04UN
LSSSGU-200
(Class D)
300 MCM
1.001
0.060
0.0370
0.050
80
750
-05UN
LSSSGU-300
(Class D)
400
1.118
0.060
0.0268
0.050
70
925
-06UN
LSSSGU-400
(127)
650 MCM
1.371
0.060
0.0170
0.060
60
1300
-07UN
LSSSGU-650
(Class D)
800 MCM
1.485
0.060
0.0138
0.060
50
1550
-08UN
LSSSGU-800
(Class D)
1000
LSSSGU-
-09UN
1.620
0.060
0.0110
0.060
40
-
MCM
1000
(Class D)
1600
LSSSGU-
-10UN
2.010
0.080
0.00693
0.075
40
-
MCM
1600
(Class B)
2000
LSSSGU-
-11UN
2.210
0.080
0.00555
0.075
35
-
MCM
2000
(Class B)