MIL-DTL-24640/22E
Heat distortion (percent of unaged, max.)
30
Cable sealant removability
No failure
Shrinkage
No failure
Surface transfer impedance
Milliohms per meter (max.)
Not applicable
EMP response (dB, min.)
Not applicable
Group D:
Flame propagation
No failure
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility (cable)
No failure
Acid gas equivalent (percent, max.)
Jacket
2
Fillers
2
Insulation
18
Halogen content (percent, max.)
Jacket
0.2
Fillers
0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.)
50
Elongation (percent of unaged, min.)
50
Smoke index (max.)
Jacket
25
Fillers
45
Insulation
10
Toxicity index (max.)
Jacket
5
Fillers
5
Insulation
1.5
Durometer (jacket) - Type A (hardness, min.)
80
Weathering (jacket)
No failure
Fungus resistance
No failure
Abrasion resistance
No failure