MIL-DTL-24640/12E
Group C:
Physicals (aged), air oven
Jacket
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
Permanence of printing
25
(conductor insulation, cycles, Method 1 only, min.)
Permanence of printing (jacket, cycles, min.)
125
Heat distortion (percent of unaged, max.)
30
Cable sealant removability (type 2XOW only)
No failure
Shrinkage
No failure
Surface transfer impedance
Milliohms per meter (max.)
700
EMP response (dB, min.)
60
Group D:
Flame propagation
No failure
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility (cable)
No failure
Acid gas equivalent (percent, max.)
Jacket
2
Fillers
2
Insulation
18
Halogen content (percent, max.)
Jacket
0.2
Fillers
0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.)
50
Elongation (percent of unaged, min.)
50
Smoke index (max.)
Jacket
25
Fillers
45
Insulation
10
6