MIL-DTL-22931/11B
REQUIREMENTS:
Operating temperature range: -55 to +80°C.
Inner conductor: See table I.
Dielectrics:
Cable core and insulating layer: See table I.
Outer conductor: See table I.
Jacket: See table I.
Voltage withstand: 3,400 volts rms (minimum) at 60 Hz, or 6,000 volts dc.
Insulation defects, spark: See table I.
Attenuation: See table I.
Velocity: See table I.
Capacitance: See table I.
Impedance: 50 ± 1 ohms.
Voltage standing wave ratio: See table I.
Mandrel size for cold bend, bending and temperature cycling tests: See table I.
Minimum bending radius: 10 inches (254.0 mm).
Part or Identifying Number (PIN): M22931/11- (dash number from table I).
6