MIL-DTL-22759/92 A
1/
TABLE IV. Tape overlap requirements.
Wrap 1
Wrap 2
Nominal
Percent
Percent
Wall
Wire
Tape
Overlap
Tape
Overlap
Thickness
Size
Code
Min
Max
Code
Min
Max
(mils)
26
1
50.5
54.0
2
50.5
54.0
5.8
24
1
50.5
54.0
2
50.5
54.0
5.8
22
1
50.5
54.0
2
50.5
54.0
5.8
20
1
50.5
54.0
2
50.5
54.0
5.8
18
1
50.5
54.0
2
50.5
54.0
5.8
16
1
50.5
54.0
2
50.5
54.0
5.8
14
1
50.5
54.0
2
50.5
54.0
5.8
12
1
50.5
54.0
3
50.5
54.0
6.7
10
1
50.5
54.0
3
50.5
54.0
6.7
1/
Wrap 1 is innermost tape which is in contact with the conductor with the 0.00045 inch FP side of the tape against the
conductor.
TABLE V.
Fluid table.
Test Fluid
Test temperature
Immersion
(°C (°F))
time (hrs.)
A. MIL-A-8243 Anti - icing and Deicing Defrosting Fluid, undiluted
48 - 50 (118 - 122)
20
B. MIL-A-8243 Anti - icing and Deicing Defrosting Fluid, diluted 60/40
48 - 50 (118 - 122)
20
(fluid/water) ratio
C. MIL-C-43616, Cleaning Compound, Aircraft Surface, Type I
48 - 50 (118 - 122)
20
D. ASTM D1153, Methyl Isobutyl Ketone (For use in Organic Coatings)
20 - 25 (68 - 77)
168
E. SAE AS 1241, Fire Resistant Hydraulic Fluid for Aircraft
48 - 50 (118 - 122)
20
F. MIL-L-7808, Lubricating Oil, Aircraft Turbine Engine, Synthetic Base
118 - 121 (244 - 250)
30
G. MIL-C-87937, Cleaning Compound, Aerospace Equipment, Type II or
63 - 68 (145 - 154)
20
Type IV, undiluted
H. MIL-C-87937, Cleaning Compound, Aerospace Equipment, Type II or
63 - 68 (145 - 154)
20
Type IV, diluted 25/75 (fluid/water) ratio
I. TT-S-735, Standard Test Fluids: Hydrocarbon, Type I
20 - 25 (68 - 77)
168
J. TT-S-735, Standard Test Fluids: Hydrocarbon, Type II
20 - 25 (68 - 77)
168
3