MIL-DTL-17/195C
REQUIREMENTS:
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Eccentricity: 10 percent maximum.
Adhesion of conductors: Not applicable.
Aging stability: +90°C ± 2°C.
Cold bend: -30°C ± 2°C.
Stress crack resistance: Not applicable.
Outer conductor integrity: Not applicable.
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .125 inch, maximum.
Contamination: Not applicable.
Bendability: Not applicable.
Flammability: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness: (Type A) 80 minimum.
Weathering: Applicable.
Abrasion resistance: 75 cycles minimum (jacket only).