MIL-DTL-17/190C
Adhesion of conductors:
Inner conductor to core: 10 pounds, minimum; 50 pounds, maximum.
Aging stability: +98°C ± 2°C.
Cold bend: -30°C ± 2°C.
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .125 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50
Elongation, percent of unaged minimum: 50
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness: (Type A) 80 minimum.
Weathering: Applicable.
Abrasion resistance: 75 cycles minimum (jacket only).
Tear strength: 35 pounds per inch minimum.
Heat distortion: 30 percent maximum distortion.
Physical tests on unaged jacket:
Tensile strength: 1,300 psi, minimum.
Elongation, 160 percent, minimum.
Physical tests on aged jacket:
Air oven:
Tensile strength, percent minimum: 60
Elongation, percent minimum: 60
3