MIL-DTL-17/182C
Elongation: 20 percent, minimum.
Engineering note: This cable is useful in balanced cables applications.
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
( (TMAX TMIN) shall be interpreted as the difference in total wall thickness measured (1) along a line
through the centers of the conductors (2) between a line tangent to the two conductors and a parallel
line tangent to the surface of the core on both sides of the conductors. The eccentricity
corresponding to the larger measured value (TMAX TMIN) shall be reported.
Adhesion of conductors:
Inner conductor to core: 2 pounds, minimum; 20 pounds, maximum.
Aging stability: +98ºC ± 2ºC.
Cold bend: -30°C ± 2°C.
Dimensional stability: +85ºC ± 2ºC.
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .125 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2 percent, maximum.
Halogen content: 0.2 percent %, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50.
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness: (Type A) 80 minimum.