MIL-DTL-17/180C
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 4 pounds, minimum; 12 pounds, maximum.
Aging stability: +98ºC ± 2ºC.
Cold bend: -30°C ± 2°C.
Dimensional stability: +85ºC ± 2ºC.
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .125 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50.
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
Toxicity index: 5 maximum.
Durometer hardness: (Type A) 80 minimum.
Weathering: Applicable.
Abrasion resistance: 75 cycles minimum (jacket only).
Tear strength: 35 pounds per inch minimum.
Heat distortion: 30 percent maximum distortion.
Physical tests on unaged jacket:
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business