MIL-DTL-17/111D
REQUIREMENTS
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination:
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 4 pounds, minimum; 15 pounds, maximum.
Aging stability: Not applicable.
Stress crack resistance: +230ºC ± 5ºC. Mandrel size: Seven times the jacket diameter.
Outer conductor integrity: Not applicable.
Cold bend: -55ºC ± 2ºC.
Dimensional stability: +200ºC ± 5ºC.
Inner conductor from core: 0.125 inch, maximum.
Inner conductor from jacket: 0.187 inch, maximum.
Contamination: Not applicable.
Bendability: Not applicable.
3