MIL-DTL-16878H
TABLE I. Details of conductors - Continued.
Maximum dc resistance of finished wire
Nominal
(ohms/1000 feet at 20 °C)
Size
Stranding
Nominal
Allowable
Diameter
diameter
desig-
(number of
conductor
number of
of conductor
Soft or
High-strength copper
of
Copper-
nation
strands
area
missing
3/
alloy
individual
annealed copper
(see
x AWG of
(circular
strands
clad
strands
1/
Min
Max
Silver-
Nickel-
Tin-
Silver-
Nickel-
mils)
1.2.4)
strands)
(max)
1/
steel
(inch)
(inch)
(inch)
coated
coated
coated coated
coated
12
6530
1 X 12
0
.0808
.0790
.082
1.620
1.680
1.690
-
-
-
12
6088
19 X 25
0
.0179
.0820
.093
1.810
1.880
1.920
-
-
-
2/
37 X 28
12
5874
0
.0126
.0840
.091
1.900
1.980
2.020
-
-
-
12
6500
65 X 30
0
.0100
.0930
.099
1.730
1.800
1.850
-
-
-
10
10380
1 X 10
0
.1019
.1000
.103
1.020
1.050
1.060
-
-
-
2/
37 X 26
10
9354
0
.0159
.1060
.115
1.190
1.240
1.260
-
-
-
10
10500
105 X 30
0
.0100
.1180
.130
1.070
1.110
1.150
-
-
-
8
16800
168 X 30
0
.0100
.1600
.175
-
-
.708
-
-
-
2/
133 X 29 /
8
16983
0
.0113
.1580
.173
.658
.694
.701
-
-
-
6
26818
133 X 27
0
.0142
.1980
.217
.418
.436
.445
-
-
-
4
42615
133 X 25
0
.0179
.2500
.274
.264
.275
.280
-
-
-
2
66140
133 X 23
0
.0223
.3300
.355
.167
.171
.176
-
-
-
2
66304
259 X 26
0
.0159
.3250
.350
.174
.180
.186
-
-
-
2/
665 X 30
2
66500
2
.0100
.3200
.342
.170
.177
.183
-
-
-
1
83916
259 X 25
0
.0179
.3700
.398
.123
.129
.144
-
-
-
1
81700
817 X 30
2
.0100
.3600
.382
.139
.144
.149
-
-
-
0
105682
259 X 24
0
.0202
.4150
.444
.103
.108
.113
-
-
-
2/
1045 X 30
0
104500
3
.0100
.4050
.431
.108
.113
.116
-
-
-
00
133460
259 X 23
0
.0227
.4670
.492
.084
.088
.090
-
-
-
2/
1330 X 30
00
133000
3
.0100
.4500
.486
.085
.089
.091
-
-
-
000
167096
259 X 22
0
.0255
.5250
.560
.069
.072
.072
-
-
-
2/
1672 X 30 /
000
167200
4
.0100
.5180
.545
.068
.071
.071
-
-
-
0000
211851
259 X 21
0
.0286
.5900
.620
.053
.055
.055
-
-
-
2/
2109 X 30
0000
210900
5
.0100
.5800
.635
.054
.056
.056
-
-
-
1/ Nominal values are for information only. Nominal values are not requirements.
2/ Preferred stranding for the associated AWG size.
3/ No high-strength copper alloy conductors above size 20.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business