MIL DTL-16878/29B
Condition 4 hours at -55±1 °C (see table II)
Cold bend:
TABLE II. Cold bend mandrel sizes.
Cold bend mandrel diameter
Wire size
(inches, maximum)
24 through 18
1
16 through 10
2
Surface resistance:
Not required
Condition at 195 °C
Heat resistance:
Heat aging:
Not required
Insulation tensile strength:
700 pounds force per square inch (minimum)
Insulation elongation:
125 percent (minimum)
Marking and stripe durability:
Not required
CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify
changes with respect to the previous issue because of the extensiveness of the changes.
CONCLUDING MATERIAL
Custodians:
Preparing activity:
Navy - SH
DLA - CC
Air Force - 11
DLA - CC
(Project 6145-2193-013)
Review activity:
Navy - AS
3