MIL-DTL-13777/6C
TABLE II. Design data Continued.
Design data
Type designation
782166S
Figure number
7
Total wires
78
Number of conductors & AWG #
64/#20
4/#20S
2/#14
2/#8
6/#4
Insulation
0.018"
Minimum average thickness
0.015"
0.025"
0.063"
Spark test voltage
3000
Inspection test voltage
1500
1800
2500
3500
Cabling
Minimum average thickness
Layer 1
Filler
Layer 2
(a) Number of wires
2
6
12
(b) AWG #
#14
#4
4/#20S
(c) Maximum lay
8
Layer 3
(a) Number of wires
66
(b) AWG #
2/#8
64/#20
(c) Maximum lay
12.00"
Sheath
Number of layers
2
Total thickness minimum
0.183"
Minimum OD cable
2.116"
Maximum OD cable
2.216"
Maximum weight (lbs./1000ft.)
2770
1/
Number of conductors and AWG# for 601665S: 35/#18, 5 Pairs, Twisted & Shielded, 15/#18S.
2/
Number of wires for layer 2 of 601665S: 5 Pairs, Twisted, & Shielded, 4/#18.
3/
Number of conductors and AWG# for 601734S: 20/#18, 20 Pairs, Twisted, & Shielded.
4/
Number of wires layer 2 for 601734S: 6 Pairs. Twisted, & Shielded.
5/
Number of wires layer 4 for 601734S: 14 Pairs. Twisted, & Shielded.
6/
Number of conductors and AWG# for 601845S: 20 Pairs, Twisted & Shielded, 20 Single Shielded.
7/
Number of wires for layer 2 of 601845S: 5 Pairs, Twisted & Shielded, 3 Singles Shielded.
8/
Number of wires for layer 3 of 601845S: 17 Shielded.
9/
Number of wires for layer 4 for 601845S: 15 Pairs, Twisted, & Shielded.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business