MIL-DTL-13486E
TABLE VII. Qualification test schedule.
Test
Number of
Length
Inspection
Test sequence
specimens
1
3 feet
Low temperature resistance (cold bend)
1
High voltage to ground
Oil absorption
1
3 feet
Low temperature resistance (cold bend)
2
High voltage to ground
Liquid immersion (salt water)
1
2 feet
Low temperature resistance (cold bend)
3
High voltage to ground
Liquid immersion (distilled water)
1
2 feet
Low temperature resistance (cold bend)
4
High voltage to ground
Liquid immersion (ethylene glycol)
1
2 feet
5
Low temperature resistance (cold bend)
High voltage to ground
High temperature resistance
1
3 feet
6
High voltage to ground
High voltage to ground
1
2 feet
7
High voltage between insulated
conductors (class B only)
8
Flammability
1
20 inches
Fungus resistance
5
3 feet
9
High voltage to ground
Ozone resistance
1
3 feet
10
Low temperature resistance (cold bend)
High voltage to ground
11
Longitudinal shifting
1
1 foot
(class B cable only)
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744