MIL-DTL-13276C
devices are usually not suitable). At the conclusion of the test, the wire shall meet the requirements for
4.7 DC resistance. The dc resistance of the wire shall be measured with a bridge having an
accuracy of at least 0.2% and shall not exceed the value specified in 3.8.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, or
in-house contractor personnel, these personnel need to contact the responsible packaging activity to
ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control
Point packaging activities within the Military Service or Defense Agency, or within the military service's
system command. Packaging data retrieval is available from the managing Military Service or Defense
Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging
activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not
mandatory.)
6.1 Intended use. Wire W-28 is intended primarily for use in antenna applications.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
b. If required, the specific issue of individual documents referenced (see 2.1).
c. Packaging requirements (see 5.1).
d. Classification of wire required (see 1.2)
e. Length of wire required.
f. Size of spool or reel and length on each.
h. Coil, spool, and reel marking requirements.
6.3 Subject term (key word) listing.
Concentric