FED-STD-228A
5. RESULTS
5.1 Unless otherwise specified in the detail specification, one specimen from each inspection unit shall
be tested.
5.2 The flammability of the fibrous covering of the insulation or sheath of the inspection unit shall be the
result obtained from the specimen tested.
5.2.1 When more than one specimen is tested, the flammability of the fibrous covering of the inspection
unit shall be the average of the results obtained from the specimens tested.
5.3 The flammability (maximum distance the specimen burned in either direction from the center point of
application of the flame) of the inspection unit shall be recorded to the nearest 1/8 inch.